6 Care and maintenance
53
6.3 Emergency draining
In the event of a blocked water outlet or drain pump, a malfunction or a power
failure, if there is water still in the appliance it must be drained off as follows:
Open drain tray 2 by pressing in the bottom area.
Or
Remove quick operating instructions 1 from the
wash detergent drawer and open drain tray 2.
Fold drain tray 2 fully down.
The drain tray also functions as a receptacle for
collecting the water being drained off.
Release the foreign body trap 3 slightly by slowly
turning it anti-clockwise. Steadily drain off the water.
From time to time the drain tray may have to emptied.
Close the foreign body trap by turning it clockwise
and remove the drain tray 2 from the front.
Empty the drain tray and then put it back in position
(push it straight in until it clicks into position).
The water in the appliance may be hot. Scalding hazard! Allow to
cool before emergency draining.
When draining off the water, the drain tray can be removed and a
larger receptacle used in its place. The appliance can hold up to
30 litres of water.